I would like to operate these switches via DCC and by the control panel. The railroad was built in the 1990's and many of the Digitrax devices used for the Kelana Jaya Rail Line model have been superseded with improved units. I have always worried 14 volts might be too high, but when I corresponded with Digitrax tech support, they didn't say anything about it. No turnouts should be connected to the DS64 at this time.2. The ratchet type like this always drop the die straight on the connector. Ya it does really bug me, specially when my NCE throttle remembers the last command set to the switch and now they are all wrong when powered up. You can configure all of the options, and assign the switch addresses for each port on the DS64 with this. The Kadee uncoupler may require as much as 3 Amps @ 22 Volts. Modeling the Reading Railroad in the 1950's. I will also check that my Loconet cables are not crossed. In your case, are you sure that the outputs just didn't lose their switch addresses ? If you have tried to program this stationary decoder and are having problems, there are several things that you can do before contacting Tech Support for further help. A typical H0 locomotive will draw 600 MA Digitrax Complete Train Control By Zana & A.J. Price: $59.99 MSRP The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. The outer sheath should be in far enough to be grabbed by the larger piece that crimps up over it. Visit my web site at www.readingeastpenn.com for construction updates, DCC Info,and more. Am I missing something here? Pins 12 and N.(directly above one another), at least 12 volts AC. My problem is that when I attach the TL5 tester to any of the four external LED connectors the four LEDs on the top light up but the LED in the center of the tester that should show zone power dose not light up. When using a DCS100 or DCS200 to setup routes within the Command Station in conjunction with DS64 Stationary Decoders, the DS64 needs to be connected to Track Power. A: One power supply can be used if it can provide adequate power forall the DS64s it is powering. You can have 4 momentary and switched button inputs. When Digitrax says set an OpSw value, it means putting the device in a program or learn mode, adn then throwing or closing the Option Switch by sending normal switch commands from the throttle. With the capacity of 8 turnouts per route, it becomes necessary to cascade routes if more than 8 turnouts are involved in a route. What is the maximum DC voltage I can apply to terminals AX1 and AX2? The gap I was talking about is not the common but between each block. However, I see now that Digitrax has replaced them with DS-74s. The PL-10 is a coil-type switch machine with double solenoids. The jacks on the front and sides of the UP5, UR92, UR91, UR90, and LNRP front panelsare Throttle Jacks and should only be used for connecting throttles to LocoNet. This typically arises on a railroad that is using power in excess of the capacities of its power supplies. Price: $29.95 MSRP When used in conjunction with the DS64 or SE8C the BD4 provides LocoNet detection for 4 occupancy detection sections. 12. My Beef with Digitrax DS 74 - YouTube It will not work for large scale turnouts. Not much action on it there. On the DS64 press and hold the OPS button down for about 3 seconds until the red OPS LED and How To Set Up Routes Using Your DS64NOTE: During this procedure the DS64 must be connected to an active LocoNet with an active command station.1. And make sure the contact area of the BDL is clean - there should be obvious marks from the edge connector if you look at it. And, of course, if you add a second locomotive, then DCC becomes the clear choice because you are not longer having to throw toggle switches just to move around the yard. I find it far more reliable to solder the wires to the pads on the Tortoise. I'm working with a Digitrax BDL168 on my test layout and intend to use it for detection but am having some problems. There might be insulating joiners but if not then the 2 wouldn't be isolated from each other. I don't see an obvious isolation between the 2 visible blocks. In addition to controlling turnouts via LocoNet with your DT400 throttle or with a computer program such as Railroad & Co., you can use local push buttons to operate turnouts. To program the DS64 Route Number, use your DCC throttle in Switch mode to select a Switch Address from 1 through 8 and issue a Closed or Thrown command. Reply IowaDCC Member since January 2013 19 posts Posted by IowaDCC on Tuesday, September 23, 2014 9:24 AM Thanks, everyone! Also did you read page 10 and solder a 10k resistor to pin 22 and common to test the unit for functionality?You can test each section before hooking up by using the 10k resistor between each output and common.There are also other instructions on power up for whole system common rail, which is what it sounds like you have. Press the SWITCH Key. 13. DS64 Quad Stationary Decoder - Digitrax I'd measure for voltage on the outputs for the track power LED, and see if there's anything there. MP5 Advanced Model Railway Turnout / Switch Motor and Digitrax DS64 Please take a look at this YouTube video I made. I am having issues with a Digitrax DS64. This is because we put a constant square wave AC current on the track and control the trains (locos) by sending messages to them (actually to receivers we call decoders) to tell them what to do such as start, stop, change directions, etc. To set up a JMRI application to use the PR3 as an interface to a LocoNet which includes a LocoNet command station: Start the program. Right, as Randy said, the tester should show the single LED islit with the track power and the 4 block occupancy lights are all out with nothing there and the power on. I did in fact try to set the opsw 6 to closed with no changes in the behavior. However, I am running a Digitrax Super Chief system and while it will remember the last switch address and command, it doesn't send them on power up. If so, is there a fix other than a trip back to the creator? KB265 DB150 Option Switch Setup The DB150 has many customizable system operation options that you can set. Are any of you successfully using DS64 stationary decoders to control Tortises? If the DS64 looses the addresses, then no matter what you send it, the outputswill stay where they power on. manage your account online and more! As a result, they are often found in high track density areas such as passenger terminals, where space is at a premium. 3. The DS64 is a powerful stationary decoder that can be used to control different devices on your railroad. Keep Good Records:Although it may seem to be a pain while setting up your Digitrax system, keeping layout records Copyright 2023 Digitrax, Inc. All Rights Reserved. How to program the Digitrax DS64 for slow motion switch machines such as the Tortoise machines on your DCC layout. Should we use the SE8C to control our slow motion switch machines, or should we use your DS64s for that function? Please visit helpdesk.digitrax.com and submit a ticket. Digitrax DS64 output #1 problem - YouTube As I was preparing to shoot a video about a successful interfacing of two DS64s with my Z21, one of the Digitrax devices broke. Troubleshooting Guides -> Stationary Decoder Troubleshooting. I'm confused here. Components used for the Kelana Jaya layout: 28 Mainline turnouts 11 Yard turnouts 39 Tortoise switch machines 84 Dwarf signals (yellow/green, red/green, red/yellow) 38 Mainline block signals 38 Heavy duty SPDT switch relays Digitrax Components Used for the Kelana Jaya layout: 1 DCS 100 DCC Automatic Reversing SectionsVirtually all automatic reversing will fall into 3 categories with the wiring principles for all being the same:1. Connect the Trk A and Trk B screw terminals of the Power and Track Connections to the corresponding Rail A and Rail B track connections. Option Switch 08-Startup Delay and Power Management Issues. Is the DS64 receiving enough power? When the jumper is open it will run solenoid turnout machines. DS64 Help Please | TrainBoard.com - The Internet's Original 20210: Kato has advised us that this unit has four solenoids in its base, each operating one turnout point set. Since thre is an OpSw that makes the 16th section the track power sensor when using common rail wiring - there could be something funky involved. Perhaps I should try powering each one individually from wall outlets, using the Digitrax PS14 or something, but that also puts out 14 volts, so I don't know how that would make things different. So he's programming it right. No. This allows for adequate current for the switches. This is another Digitrax engineering/design problem that should be corrected rather than shrugging it off. Q: If I have only 3 turnouts on a DS64, to complete the 4 point programming I have been inputting a bogus turnout number. Digitrax DS 64 - page 1 - DCC / Electronics - TheRailwire If you are planning to use the contacts on the Tortoises to route power to the frogs or points, I strongly advise against using edge connectors on the Tortoise. What Digitrax equipment would I need? The DCS100/200 does not send internal route messages via LocoNet. When using more than one DS64 in a DCC environment, you must assign a Board ID to each additional DS64 so that each one has a unique Board ID.You will need to set the DS64's board ID if you are planning to use the DS64's 8 inputs with a computer, system throttle, or other smart device on your layout that needs to know when a turnout has been manually thrown or closed via a particular DS64.You can use the 8 inputs on the DS64 to control the operation of the 4 outputs that control your turnouts. Also, we show how to wire the input and o. This example is a small yard with a crossing signal at its entrance. TurntablesDCC has the ability to automatically reverse sections of track we call Reversing Sections while our trains are running and not affect the direction or speed of the trains. Can a DS-74 control two turnouts at the same time? That makes me think that either you didn't actually close OpSw 6, or something (maybe another throttle, or a macro?) To open this tool select "Configure DS64" from the LocoNet menu for the connection this DS64 is attached to. OpSw 02 = Closed the pulse width is 200ms (milliseconds). In my opinion, the DS64 is more versatile. Connecting a 12v dc power supply to the DS64 will not programme it, only connection to a LocoNet cable network ( not an option for you ) and the programming track addressed by the NCE controller will work to address this decoder. See Knowledge Base article. Or, without having to create a logon and open a ticket, you can simply go to the DS74 product page and read the doc to get your answers. How are you powering the DS64? manage your account online and more! Yes forgot to list the ground from the DCS50 to pin #11 and I am powering the BDL168 with 12V to pin 12 and N. Track Power is on, and gaps are good. CEO- Mile-HI-RailroadPrototype: D&RGW Moffat Line 1989. DC Control For DC operation, Atlas specified an Atlas Controller (for the reverse loop), two Atlas Selectors (to control eight track segments) and seven controllers for the railroad's turnouts. Turn off the track power, and you should get what the tester shows in the pic: the single LED is out, and the 4 occupancy lights are on. Although it is possible to power the DS64 from track power, this has been a source of problems for many operators due to low voltage. Can I hook up the DS51K1 stationary decoder in addition to this wiring? Unless you do a lot of work to ensure that there is absolutely no way that the edge connector can shift either way and thereby prevent its contacts from shorting two pads on the Tortoise, you run the risk of the connector shifting and shorting across the track power and DS64 output pad. I picked up an accessory booster and it seemed to do the trick. As always, I look forward to reading the replies. Set DS64 OptionSwitches 11 and 15 to 'c' closed to enable route commands from local inputs. Because each locomotive has a unique address, the section insulated gaps and the two Selectors are not necessary. Follow this procedure and every cable will be a good one (unless you stick one on upside downa nd make a telco cable by accident). Individual turnouts operate by throttle command, routes work with throttle command BUT when route is executed it not only throws the route specific to DS64 #2, it also throws individual turnouts assigned to DS64 #1. The Tortoise, while also a slow motion point motor, is "on" all the time since it is a stall-type motor. This forum is so helpful. I was wondering if it was possible to use the DS64 to create a closed connection (relay output) to activate this connection for the turntable position. Kato has offered a variety of turnouts in their H0 Unitrack line.381-2840 - LH, 490mm Radius, selectable operating mode with power or non-power routing.381-2841 - RH 490mm Radius, selectable operating mode with power or non-power routing.381-2850 - LH, #4, power routing only. 1: DS54 - difficult to program - must set on board jumper and for some functions must be disconnected from track and connected to a programming track DS64 - push button programming and after board address is set you can use Decoder Pro to program it. The DS64 is a powerful stationary decoder. In addition to the route You can automate grade crossing signal lights with block occupancy sensors. Under what conditions can the PR3 be used as a Stand Alone LocoNet Terminator? This lets the DS64 know which of the 8 available routes you are setting up. 11 All, I have a digitrax DS64 powered by a 12.3 VDC Power Supply going through AX1 (-) and AX2 (+) terminals. To properly use your DS52 you must be sure these jumpers are in the correct position. A quick demo for how to use a Digitrax DS64 Quad Stationary Decoders to control turnouts on the Mon-Yough Valley mainline at McKeesport Model Railroad Club Just my guess, hardto see in pictures. A classic bowl of spaghetti, the Transbay Interwoven has two reversing loops and a turntable. Search for troubleshooting guides. This wasn't an issue for me, but obviously is for you. But if it really bugs you, try closing OpSw 6. Watched your video, and noticed you said you changed "Switch 1" to closed (at about 4:20). Yes, there may be only one locomotive on many of these railroads, but that locomotive can still benefit from DCC. It has already happened to me, causing a derail as soon as the train started moving. Each DS64 present on LocoNet is identified uniquely by its "Board ID". Digitrax BDL168 problems? - Model Railroader Magazine - Model Set the following OpSw's (not all the default! When I called Digitrax about this they said it was a known issue and that the engineer who wrote the program did this, and he is gone. No. The DS64's approximate size:12cm (length) x 8.8cm (width) x 3.5cm (height)4.75" (length) x 3.5" (width) x 1.4" (height)The front edge of the DS64 needs clearance for wires to be attached. This tool may access a particular DS64 by entering the Board ID number in the selection box at the top of the window. If you have a PC to Loconet connection (PR3, Locobuffer, etc), download a copy of Loconet Checker. Can I plug the DS-74s into this buss using the TKA and TKB ports. Also looking at the feeders to the track in the pic. This isn't just theory or speculative hand-wringing-- I've spent an awful lot of time replacing DS64s that have had outputs blown in this manner, and no longer support this kind of installation for my customers. DCC Makes Things Simple With DCC, the wiring of this railroad is considerably simpler. The solution is to connect pin 10 of the DS1 on the BD4 to a system ground such as the AX1 terminal of the DS64, Ground on the booster terminal, etc. In case anyone finds this and doesn't see an answer: 1. Automatic DS74 switch address overlap detection, and correction capability when editing with DT602. He has 3 detection sections. The DS64 is shipped from the factory with these outputs programmed as Switch Addresses 01, 02, 03, and 04 respectively. NOTE: Use only the rear power jack or Before sending your Digitrax DS54 stationary decoder in for repair try these steps to see if you can bring it back from the dead and save a trip to the shop and possible repair charge.If you find you need to send in an item for repair, click here For Digitrax Repair Procedures and InformationAre there burn marks on the DS54 decoder?You'll need to send it in for repair!Understand CV programming with different throttleCV values shown are 00 or 000 for decimal and x00 for hex. Digitrax DS64 Quad Stationary Decoder - dcctrainautomation.co.uk Labels? Make sure your Loconet cables are correct - a flipped over one will cause issues with a BDL168, it's one of the few devices where it actually matters. What's that Yoda quote, "Do or do not there is no try!". To reset DCS52, DCS210 or DCS240 close Option Switch 40. . Can support on expansion header up to 4 DSXCP1 fascia SW control panels with SW direction indicator LEDs. If you are using solenoid type turnouts, you can install the DS64 out of the box. If you have reconfigured your DS64 for stall motor type turnouts, the DS64 can be reconfigured back to solenoid type turnout motors.1. The DS64 can be powered in several different ways. 2 TEAMYAKIMA Members 3.3k Posted June 23, 2022 I regret that I am still getting problems with DIGITRAX (in general) even though tens of thousands of people around the world rave about the brand. Thanks again for your thoughts on this! Thanks,fmilhaupt. With a wall plug or through your track power? The rail B from the DCS50 is connected to the far rail on my test track. When the DS64 tries to operate Fulgurex motor, the excess current draw appears to be a short circuit and the DS64 shuts down to protect itself. Connecting the DS51K1 to the red / black wire pair at the base of the track will damage the decoder since the four solenoids of the crossover will draw more than the rated current capacity of the DS51K1. So modelers have learned to power their accessory decoders from a separate booster to avoid these problems. The Digitrax technical support got back to me and told me to send it in. Doing it right now. Contact Digitrax. Same things are being posted ont eh Digitrax Yahoo group - first post was "what about the ground" whichw as clarified by the OP - he DOES have the ground wirein place. Digitrax DS64 Problems Model Railroading > Digitrax DS64 Problems Date: 06/26/15 20:39 Digitrax DS64 Problems Author: BlackWidow Are any of you successfully using DS64 stationary decoders to control Tortises? I've had a lot of kooky things happen with our 7 BDL168's, but never that. A: Bothproducts will do the job.
Vidiq Competition Score, Laravel 9 Stripe Checkout, Indoor Volleyball Shoes, Laravel 9 Stripe Checkout, Sweet Himalayan Detox Green Tea Benefits, Scheepjes Whirl Golden Glowworm, Mares Matrix Dive Computer Manual, Used Kayaks For Sale New Jersey, Conditioner For Sensitive Scalp, Pros And Cons Of Hyundai Tucson Hybrid, Long Rubber Gloves For Dishwashing, Dotstar Digital Led Strip,




